After-sales Service: | 12 Months |
---|---|
Warranty: | 12 Months |
Certification: | ISO, CCC, CE, RoHS, VDE |
Still deciding? Get samples of US$ 50/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
• Conductor: Class 1 Solid Copper Class 2 stranded Copper or Aluminum
• PVC/XLPE insulation
• Filler: Polypropylene lament with lapped binding tape
• PVC inner sheath
• Core-covering: Binding tape
• PVC outer sheath
PVC/XLPE Insulated Power Cable meets or exceeds the following standards: IEC 60502, BS, DIN, ASTM, GB12706-2008 standards.
XLPE power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.
Rated Voltage, No. of Core, and Range of Sectional Area
Rated voltage (kV) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
Rated voltage Uo (kV) Item |
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | ||
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 | |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | ||
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 | |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
No.of cores x Nominal section area | Nominal Construction of conductor | Nominal Insulation thickness |
Nominal Sheath thickness |
Nominal Overall diameter |
Nominal Cable weight |
Max.Resistance of conductor at 20ºC |
No.X mm² | No.X mm | mm | mm | mm | kg/km | <=(Ω/km) |
Four core XPLE Power Cables CU/XLPE/PVC( AL/XLPE/PVC ) | ||||||
4x1.5 | 2x 1.38 | 0,7 | 1,8 | 12.1 | 150 | 12,10 |
4x2.5 | 7 x 0,67 | 0,7 | 1,8 | 13.2 | 200 | 7,41 |
4x4.0 | 7 x 0,85 | 0,7 | 1,8 | 14.9 | 275 | 4,61 |
4x6.0 | 7 x 1,04 | 0,7 | 1,8 | 16.1 | 370 | 3,08 |
4x10 | 7 x 1,35 | 0,7 | 1,8 | 18.6 | 560 | 1,83 |
4x16 | 7 x 1,70 | 0,7 | 1,8 | 20.2 | 795 | 1,150 |
4x25 | 7 x 2,14 | 0,9 | 1,8 | 21.8 | 1130 | 0,727 |
4x35 | 7 x 2,52 | 0,9 | 1,8 | 24.1 | 1515 | 0,524 |
4x50 | 19 x 1,78 | 1,0 | 1,9 | 27.5 | 2010 | 0,387 |
4x70 | 19 x 2,14 | 1,1 | 2,0 | 31.7 | 2860 | 0,268 |
4x95 | 19 x 2,52 | 1,1 | 2,1 | 35.4 | 3870 | 0,193 |
4x120 | 37 x 2,03 | 1,2 | 2,3 | 39.2 | 4850 | 0,153 |
4x150 | 37 x 2,25 | 1,4 | 2,4 | 43.8 | 5980 | 0,124 |
4x185 | 37 x 2,52 | 1,6 | 2,6 | 48.7 | 7480 | 0,0991 |
4x240 | 61 x 2,25 | 1,7 | 2,8 | 54.4 | 9735 | 0,0754 |
4x300 | 61 x 2,52 | 1,8 | 3,0 | 59.9 | 12120 | 0,0601 |