After-sales Service: | Guarantee Repair |
---|---|
Warranty: | 1 Year |
Application: | Oil Tanker, Chemical Tankers, Public Services Ship |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type(PLKD_.C) | 24 | 32 | 40 | 48 | 64 | 80 | 100 | 120 | 150 | |
Nominal WP(MPa) | 0.8MPa | 1.0MPa | 1.2mPa | 1.4MPa | ||||||
Pressure Range(MPa) | 0.4-1.2MPa | 0.4-1.4MPa | ||||||||
Flow Rate(L/S) | Foam | 24 | 32 | 40 | 48 | 64 | 80 | 100 | 120 | 150 |
Water | 24 | 32 | 40 | 48 | 64 | 80 | 100 | 120 | 150 | |
Range(m) | Foam | >=40 | >=48 | >=55 | >=60 | >=70 | >=80 | >=85 | >=90 | >=95 |
Water | >=45 | >=55 | >=65 | >=70 | >=75 | >=85 | >=95 | >=95 | >=100 | |
Horizontal Rotate Angle(°) | 270° | |||||||||
Pitching Angle(°) | -30~+60° | |||||||||
Expansion Rate(20ºC) | >=6 | |||||||||
25%Drainage Time(20ºC) | >=2.5min | |||||||||
Power | AC380V/50Hz: DC24V | |||||||||
Motor Power | 0.37KW | |||||||||
Inspection Standard | General Specifications for Fire Monitors: General Specifications for Remote Controlled Fire Monitor Systems |